0.45/0.75KV Single Core Standard Wall Traction Cables

 

Applications :

  • Single core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts.

Standards :

  • BS 6853 -1a
  • DIN 5510-1 1-4
  • NFF 16-101 F0
 

 

Construction :

  • Conductor : Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
  • Insulation : Electron beam crosslinkable standard wall LSZH compound.

Optional :

  • FRA-SW-0.75S (Sheathed); FRA-SW-0.75S-OS (Screened & sheathed)
  • FRA-SW-0.75SU-FR (Fire resistant & Unsheathed)

Electrical Characteristics at 20 °C :

  • Nominal Conductor Cross Section mm² 1.0 1.5 2.5 4.0 6.0 10 16
    Maximum Conductor Resistance Ω/km 20 13.7 8.21 5.09 3.39 1.95 1.24
    Voltage Rating KV 0.45/0.75

Mechanical and Thermal Properties :

  • Minimum Bending Radius : 3×OD (OD<12mm); 4×OD (OD>12mm)
  • Temperature Range : -40°C to +120°C.

Dimensions and Weight :

 

Cable Code No. of cores& Nominal
Conductor Cross Sectional Area
No.×mm²
Nominal Diameter
of Strands
mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
FRA-SW-0.75SU-1G1 1×1.0 32/0.2 0.8 3.9 28
FRA-SW-0.75SU-1G1.5 1×1.5 30/0.25 0.8 4.2 34
FRA-SW-0.75SU-1G2.5 1×2.5 50/0.25 0.8 4.6 41
FRA-SW-0.75SU-1G4 1×4.0 56/0.3 0.8 5.2 64
FRA-SW-0.75SU-1G6 1×6.0 84/0.3 0.9 6.4 93
FRA-SW-0.75SU-1G10 1×10.0 80/0.4 0.9 7.5 141
FRA-SW-0.75SU-1G16 1×16.0 126/0.4 1.1 8.6 203

 

 

 

Impact Resistant
Highly Flexible
UV Resistant
Oil Resistant
Weather Resistant
Low Toxicity

 

 

Flame Retardant
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1
Fire Retardant
NF C32-070-2.2(C1)
IEC 60332-3/EN50266
Zero Halogen
IEC 60754-1/NF C20-454
EN 50267-2-1
Low Smoke Emission
IEC 61034/NFC20-902
EN 50268/NF C32-073
Low Corrosivity
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453